HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Appendix C Revision 8
C–3
C.2.2 Install the New Power Supply
To install the new power supply, do these steps:
Visually inspect the exposed SSPA heat sink for any debris or blockage. Use compressed air to clean
and clear as needed.
Visually inspect both the SSPA and power supply connector for cleanliness or damage. Clean and
correct as required.
Inspect the gasket for damage. Replace as required.
Install the power supply onto the SSPA. Make sure that the guide pins and connection are properly
aligned. Gently press to engage the connector.
Tighten the four captive fasteners where shown previously in Figure C-1.
Be sure to use an appropriate screwdriver, such as the one provided
with the SSPA, to avoid damaging the fasteners.
Reconnect the HPOD SSPA to its power source.