INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
15
4. TERMINATION
4.1 We would recommend the use of a suitably approved anti-
down draught cowl for gas operation.
Anit-down
draught cowl
(Approved for gas
use)
Cement Mortar
Plate Clamp
Brick Chimney
Stainless Steel
Flexible Flue
Liner
Back fill with Vermiculite
Insulation or similar
Bends must be no less than
135°
Vitreous Enamelled Steel or
Stainless Steel with Cleaning
Cover
Seal Liner
into Flue Socket
with Fire Cement
MIN RISE
BEFORE
BEND
=600MM
MIN EFFECTIVE HEIGHT=3M
CONVENTIONAL BRICK CHIMNEY WITH LINER
3
DO NOT USE GCI GAS TERMINALS