Redfyre parts appropriate cleaning
methods
Hot water & soap
Wire Brush
Cream cleaner
Nylon Brush
V.E.D.C. cleaners
Top Plate
Vitreous enamel
3 3 3
Surround
3 3 3
Hot plates
3 3 3 3
Oven
Internal
3
3 3 3
Shelves
3 3 3
Oven
Internal
3
3 3
Seal
3 3
Oven
Front 3
Sides
3
Doors
3
Chrome handles
3
Towel rail
3
Top plate
3 3 3
Hotplate lids
3
9. COMBUSTION PRODUCTS DISCHARGE
SAFETY DEVICE (TTB)
9.1 This sensor monitors the safe performance of the flue and is
located in the diverter on the flue outlet. This important
safety device prevents products of combustion entering a
room.
9.2 The flue sensor switches the burner off if the flue
performance is not good enough. You must wait 30 minutes
before you can press the reset button in the control panel to
relight the cooker. Refer to diagram 2
2
AR1551
9.3 When there is repeated shutdown of the cooker, the flue/
chimney must be investigated immediately:
• Turnthegasburneroff
• Contactacompetentserviceengineertoinspectthe
cooker
10. RUNNING IN
10.1 The new surface coating on your Redfyre cooker “burns off”
to create a harmless odour during its first hours of use. The
smell disappears after a short period but if it persists ask
your installer for advice.
11. SERVICING
11.1 The cooker must be serviced every 12 months by a
qualified gas engineer. In all correspondence, always quote
the model and serial number found on the data badge.
11.2 You must turn off your cooker 12 hours before servicing.
Your cooker cannot be serviced while it is hot.
12. VENTILATION
12.1 Heat and moisture are produced by gas range cookers.
• Ensurethekitcheniswellventilated
12.2 You may need to open a window or increase mechanical
ventilation during prolonged use of the cooker.
12.3 Air for combustion is taken in through the cooker’s burner
door.
• DONOTshutofforblockthisdoororanyadditionalair
vents fitted by your installer in any compartment or to the
outside
12.4 Any purpose-provided ventilation should be periodically
checked to ensure that it is free from obstruction.
12.5 If a gas hob is installed in the four-oven version, then 30
cm
2
(4.5”2) of extra ventilation is required.
13. INSTRUCTION DETAILS
13.1 The Commissioning sheet at the front of this book must be
completed by your installer to help with any future
correspondence. This records the essential installation
details. In all correspondence you must quote the model
and serial number.
USER INSTRUCTIONS